Flexible Control and Flexible Power Cable (600 Volt )

HomeIndustrial CableFlexible Control and Flexible Power Cable (600 Volt )
Flexible Control and Flexible Power Cable (600 Volt ) 2017-06-29T16:57:06+00:00

Project Description

XLPE/Nylon/HYP Thermoset Super Flexing Control Cable

XLPE/Nylon/HYP Thermoset Super Flexing Control Cable
UL Type TC/CSA CIC, 600 V

We’re sorry, but this cable is no longer available. Please call us at 800-472-4655 or email us and we will help you find a suitable alternative.

XLPE/Nylon/HYP Thermoset Super Flexing Control Cable Approvals:

  • Industry Compliances:
    • UL Type TC / CSA CIC
  • Flame Tests Compliances:
    • IEEE 1202 (70,000 BTU/hr) CSA FT4
    • IEEE 383 (70,000 BTU/hr)
  • Other Compliances:
    • Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA acceptable

XLPE/Nylon/HYP Thermoset Super Flexing Control Cable Construction:

  • Conductor:
    • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3
    • Class M: 18 AWG thru 16 AWG
    • Class K: 14 AWG thru 10 AWG
    • Stranding per ASTM B8
  • Insulation:
    • Thermoset Cross-Linked Polyethylene (XLPE) with clear Polyamide (nylon)
  • Color-Coded:
    • All conductors red, except #2 is white and #3 is green, all with alpha-numeric designations
  • Jacket:
    • Lead-Free Hypalon Chlorosulfonated Polyethylene (CSPE)/Elastomer blend

XLPE/Nylon/HYP Thermoset Super Flexing Control Cable Applications:

  • Any continuous flexing application requiring a small diameter flexible cable
  • ROBOTS
  • Machine tools
  • Car body and vehicle assembly
  • Material handling equipment
  • Power tracks

XLPE/Nylon/HYP Thermoset Super Flexing Control Cable Features:

  • Rated at 90°C, 75°C wet
  • Extremely flexible with long flex life
  • Small diameter
  • Thermoset rubber insulation and jacket
  • Oil resistant
  • Suitable for indoor and outdoor applications
  • Meets cold bend test at -30°C
  • Meets cold impact test at -25°C
Part NumberAWG SizeNo. of Cond.Conductor StrandingNom. O.D. (in)Nom. Insul. Thick. (in)Approx LBS/MFTJacket ThickMin. Bend Radius
169475-1818641/340.3900.02093.0453.0
169480-1818841/340.4550.020116.0453.5
169485-18181241/340.4900.020155.0454.0
169490-18181641/340.5700.020211.0604.5
169495-18182241/340.6500.020272.0605.0
169500-18183141/340.7500.020366.0606.0
169505-18184141/340.8800.020498.0807.0
169510-18186041/341.0000.020676.0808.0
169515-1816665/340.4300.020122.0453.5
169520-1816865/340.4900.020152.0454.0
135115-18161265/340.5750.020216.0604.5
108695-18161665/340.6300.020277.0605.0
109495-18162265/340.7250.020368.0605.5
262155-18163165/340.8350.020491.0606.5
109485-18164165/340.9850.020683.0808.0
355290-18166065/341.1150.020912.0809.0
169525-1814641/300.4600.020159.0453.5
169530-1814841/300.5600.020219.0604.5
169535-18141241/300.6200.020295.0605.0
169540-18141641/300.6800.020375.0605.5
169545-18142241/300.7850.020495.0606.0
132490-1812665/300.5550.020238.0604.5
169550-1812865/300.6350.020300.0605.0
113065-18121265/300.7050.020433.0605.5
169555-18121665/300.7800.020535.0606.0
169560-18122265/300.9450.020789.0807.5
169565-18106105/300.6550.026350.0605.0
169570-18108105/300.7550.026450.0606.0
169575-181012105/300.8850.026675.0807.0
169580-181016105/301.1450.026905.0809.0
PVC/Nylon/HYP Thermoset Continuous Flexing Control Cable
We’re sorry but PVC/Nylon/HYP Thermoset Continuous Flexing Control Cable is no longer available for purchase. Please call us at 800-472-4655 or email us and we will help you find a suitable alternative.

PVC/Nylon/HYP Thermoset Continuous Flexing Control Cable

UL Type TC/CSA AWM, 600 V

PVC/Nylon/HYP Thermoset Continuous Flexing Control Cable Approvals:

  • Industry Compliances:
    • UL Type TC / CSA AWM
    • Flame Tests Compliances:
    • IEEE 1202 (70,000 BTU/hr) CSA FT4
    • IEEE 383 (70,000 BTU/hr)
  • Other Compliances:
    • Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA acceptable

PVC/Nylon/HYP Thermoset Continuous Flexing Control Cable Construction:

  • Conductor:
    • 18 AWG thru 12 AWG fully annealed stranded bare copper per ASTM B3
    • Class M: 18 AWG thru 16 AWG
    • Class K: 14 AWG thru 12 AWG
    • Stranding per ASTM B8
  • Insulation:
    • Flame Retardant Polyvinylchloride (PVC) with clear Polyamide (nylon)
  • Color-Coded:
    • All conductors red, except #2 is white and #3 is green, all with alpha-numeric designations
  • Jacket:
    • Lead-Free Hypalon Chlorosulfonated Polyethylene (CSPE)/Elastomer blend

PVC/Nylon/HYP Thermoset Continuous Flexing Control Cable Applications:

  • Any continuous flexing application requiring a small diameter flexible cable
  • ROBOTS
  • Machine tools
  • Car body and vehicle assembly
  • Material handling equipment
  • Power tracks

PVC/Nylon/HYP Thermoset Continuous Flexing Control Cable Features:

  • Rated at 90°C
  • Extremely flexible with long flex life
  • Small diameter
  • Thermoset rubber jacket
  • Oil resistant
  • Suitable for indoor and outdoor applications
  • Meets cold bend test at -40°C
Part NumberAWG SizeNo. of Cond.Conductor StrandingJacket ThickNom. O.D. (in)Approx LBS/MFTNom. Insul. Thick. (in)Min. Bend Radius
169235-1818641/34.0450.390093.0203.0
169240-1818841/34.0450.4550116.0203.5
169245-18181241/34.0450.4900155.0204.0
169250-18181641/34.0600.5700211.0204.5
169255-18182241/34.0600.6500272.0205.0
169260-1816665/34.0450.4300122.0203.5
169265-1816865/34.0450.4900152.0203.9
169270-18161265/34.0600.5750216.0204.5
169275-18161665/34.0600.6300277.0205.0
169280-18162265/34.0600.7250368.0205.5
169285-1814641/30.0450.4600159.0203.7
169290-1814841/30.0600.5600219.0204.5
169295-18141241/30.0600.6700295.0205.0
169300-18141641/30.0600.6800375.0205.5
169305-18142241/30.0600.7850495.0206.0
169310-1812665/30.0600.5550238.0204.5
169315-1812865/30.0600.6350300.0205.0
169320-18121265/30.0600.7050433.0205.5
169325-18121665/30.0600.7800535.0206.0
169330-18122265/30.0800.9450789.0207.5
PVC/Nylon/Neoprene Thermoset Flexible Control Cable
PVC/Nylon/Neoprene Thermoset Flexible Control Cable
UL Type TC, 600 V

PVC/Nylon/Neoprene Thermoset Flexible Control Cable Approvals:

  • Industry Compliances:
    • UL Type TC – 600V
  • Flame Tests Compliances:
    • IEEE 1202 (70,000 BTU/hr)
    • IEEE 383 (70,000 BTU/hr)
  • Other Compliances:
    • Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA acceptable

PVC/Nylon/Neoprene Thermoset Flexible Control Cable Construction:

  • Conductor:
    • 18 AWG thru 12 AWG fully annealed stranded bare copper per ASTM B3
    • Stranding per ASTM B8
  • Insulation:
    • Flame Retardant Polyvinylchloride (PVC) with clear Polyamide (nylon)
    • Color-Coded: per ICEA method 1:
    • Table E-2 (Does not include white or green)
  • Jacket:
    • Thermosetting Neoprene

PVC/Nylon/Neoprene Thermoset Flexible Control Cable Applications:

  • Tight installations
  • Trays, conduits and raceways
  • Cranes and hoists
  • Pendant stations
  • Load lifts and platforms
  • Recommended for moderate flex applications

PVC/Nylon/Neoprene Thermoset Flexible Control Cable Features:

  • Rated at 90°C
  • Moderate flex cable
  • Small diameter
  • Thermoset rubber jacket
  • Flame retardant
  • Suitable for indoor and outdoor applications
  • Meets cold bend test at -40°C
Part NumberAWG SizeNo. of Cond.Conductor StrandingJacket ThickNom. Insul. Thick. (in)Nom. O.D. (in)Approx LBS/MFTMin. Bend Radius
277210-1818419/.0092.045.0200.3100652.5
312370-1818819/.0092.045.0200.42001163.3
312375-18181019/.0092.045.0200.45001353.6
312380-18181219/.0092.045.0200.46501373.7
312005-18181619/.0092.045.0200.51501754.1
312390-18181919/.0092.060.0200.57001924.6
312395-18182419/.0092.060.0200.66002975.3
343445-18183019/.0092.060.0200.69503455.6
312580-1816419/.0117.045.0200.3450852.8
312600-1816819/.0117.045.0200.46501533.7
312610-18161019/.0117.045.0200.50001794.0
312615-18161219/.0117.045.0200.52001864.2
312625-18161619/.0117.045.0200.60502574.8
312635-18161919/.0117.060.0200.63503205.1
312640-18162419/.0117.060.0200.73504035.9
312645-18163019/.0117.060.0200.77504766.2
312475-1814419/.0147.045.0200.37501173.0
312490-1814819/.0147.045.0200.48501813.9
312495-18141019/.0147.060.0200.59502704.8
312500-18141219/.0147.060.0200.61502784.9
312510-18141619/.0147.060.0200.67503535.4
312515-18141919/.0147.060.0200.71004495.7
312520-18142419/.0147.060.0200.82505656.6
312525-18143019/.0147.080.0200.92007277.4
162410-1812419/.0185.045.0200.4200157304
312425-1812819/.0185.060.0200.57502724.6
312430-18121019/.0185.060.0200.67003695.
312435-18121219/.0185.060.0200.69003895.5
312445-18121619/.0185.060.0200.76505036.1
312450-18121919/.0185.060.0200.80506386.5
312455-18122419/.0185.080.0200.98008417.8
312460-18123019/.0185.080.0201.040010178.3
PVC/Nylon/Nitrile/PVC Thermoset Continuous Flexing Control Cable
PVC/Nylon/Nitrile/PVC Thermoset Continuous Flexing Control Cable
UL Type TC/CSA AWM, 600 V

PVC/Nylon/Nitrile/PVC Thermoset Continuous Flexing Control Cable Approvals:

  • Industry Compliances:
    • UL Type TC/CSA AWM
  • Flame Tests Compliances:
    • IEEE 1202 (70,000 BTU/hr)
    • IEEE 383 (70,000 BTU/hr)
  • Other Compliances:
    • Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA acceptable

PVC/Nylon/Nitrile/PVC Thermoset Continuous Flexing Control Cable Construction:

  • Conductor:
    • 16 AWG fully annealed stranded bare copper per ASTM B3
    • Class M stranding per ASTM B8
  • Insulation:
    • Flame Retardant Polyvinylchloride (PVC) with clear Polyamide (nylon)
  • Color-Coded:
    • All conductors red, except #2 is white, the last conductor in each construction is green/yellow. All with alpha-numeric designations.
  • Jacket:
    • Thermosetting Nitrile/Polyvinylchloride (PVC)

PVC/Nylon/Nitrile/PVC Thermoset Continuous Flexing Control Cable Applications:

  • Any continuous flexing application requiring a small diameter flexible cable
  • ROBOTS
  • Machine tools
  • Car body and vehicle assembly
  • Plant automation equipment
  • Flexible cable tracks

PVC/Nylon/Nitrile/PVC Thermoset Continuous Flexing Control Cable Features:

  • Rated at 90°C dry, 75°C wet
  • Flame retardant
  • Small diameter
  • Oil resistant
  • Thermoset rubber jacket
  • Meets cold bend test at -25°C
Part NumberAWG SizeNo. of Cond.Conductor StrandingJacket ThickNom. O.D. (in)Approx LBS/MFTNom. Insul. Thick. (in)Min. Bend Radius
169230-18161165/34.0600.5800190.0204.50
146975-18161265/34.0600.5800195.0204.50
169220-18161665/34.0600.6350251.0205.00
153825-18161765/34.0600.6700275.0205.25
146980-18161965/34.0600.7050304.0205.50
155940-18162165/34.0600.7700339.0206.00
153210-18162265/34.0600.7700346.0206.00
144005-18162565/34.0600.8150401.0206.50
169225-18163165/34.0800.8900483.0207.00
146985-18163365/34.0800.8900506.0207.00
144010-18164165/34.0800.9750622.0207.75
153830-18164265/34.0800.9750629.0207.75
146075-18164765/34.0801.0250684.0208.25
153685-18164965/34.0801.0550724.0208.50
146990-18166065/34.0801.1250851.0209.00
146080-18166565/34.0801.1800927.0209.50
PVC/Nylon/PVC Thermoplastic Flexible Control Cable
PVC/Nylon/PVC Thermoplastic Flexible Control Cable
UL Type MTW/CSA AWM, 600 V

PVC/Nylon/PVC Thermoplastic Flexible Control Cable Approvals:

  • Industry Compliances:
    • UL Type MTW/CSA AWM
  • Other Compliances:
    • Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA acceptable
    • RoHS compliant

PVC/Nylon/PVC Thermoplastic Flexible Control Cable Construction:

  • Conductor:
    • 18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3
    • Class M: 18 AWG thru 16 AWG
    • Class K: 14 AWG thru 10 AW
    • Stranding per ASTM B8
  • Insulation:
    • Flame Retardant Polyvinylchloride (PVC) with clear Polyamide (nylon)
    • Color-Coded:
      • All conductors red, except #2 is white and #3 is green. All with alpha-numeric designations.
  • Jacket:
    • Heat, moisture and oil resistant Polyvinylchloride (PVC)

PVC/Nylon/PVC Thermoplastic Flexible Control Cable Applications:

  • Pendant cable
  • Machine tool
  • Internal machine connections
  • Material handling equipment
  • Moderate flex

PVC/Nylon/PVC Thermoplastic Flexible Control Cable Features:

  • Rated at 90
  • Moisture and oil resistant
  • Heavy-duty PVC jacket
  • Meets cold bend test at -25°C
Part NumberAWG SizeNo. of Cond.Conductor StrandingJacket ThickNom. O.D. (in)Approx LBS/MFTNom. Insul. Thick. (in)Min. Bend Radius
169585-1818641/34.0450.400088.0203.0
169590-1818841/34.0450.4550108.0203.5
169595-18181241/34.0450.5000144.0204.0
169600-18181641/34.0600.5800196.0204.5
169605-18182241/34.0600.6600252.0205.0
169610-18183141/34.0600.7600325.0206.0
169615-18184141/34.0800.8900460.0207.0
169620-18186041/34.0801.0100617.0208.0
169625-1816665/34.0450.4400113.0203.5
169630-1816865/34.0450.5000141.0204.0
169635-18161265/34.0600.5850214.0204.5
169640-18161665/34.0600.6400263.0205.0
169645-18162265/34.0600.7350377.0205.5
169650-18163165/34.0600.8450518.0206.5
169655-18164165/34.0800.9950652.0208.0
169660-18166065/34.0801.1250909.0209.0
169665-1814641/30.0450.4700149.0203.5
169670-1814841/30.0600.5700204.0204.5
169675-18141241/30.0600.6300279.0205.0
169680-18141641/30.0600.6900354.0205.5
169685-18142241/30.0600.7950467.0206.0
169690-1812665/30.0600.5650226.0204.5
169695-1812865/30.0600.6450289.0205.0
169700-18121265/30.0600.7150398.0205.5
169705-18121665/30.0600.7900506.0206.0
169710-18122265/30.0800.9550720.0207.5
169715-18106105/30.0600.6650329.0265.0
169720-18108105/30.0600.7650424.0266.0
169725-181012105/30.0800.8950604.0267.0
169730-181016105/30.0801.1550852.0269.0
PVC/PVC Thermoplastic Festoon Control Cable

We’re sorry but PVC/PVC Thermoplastic Festoon Control Cable is no longer available for purchase. Please call us at 800-472-4655 or email us and we will help you find a suitable alternative.

PVC/PVC Thermoplastic Festoon Control Cable
UL Type Festoon, 600 V

PVC/PVC Thermoplastic Festoon Control Cable Approvals:

  • Industry Compliances:
    • UL Listed/CSA certified flat festoon cable
  • Flame Tests Compliances:
    • UL VW-1/CSA FT1
  • Other Compliances:
    • Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
    • OSHA acceptable

PVC/PVC Thermoplastic Festoon Control Cable Construction:

  • Conductor:
    • 16 AWG thru 2 AWG fully annealed stranded bare copper per ASTM B3
    • Class M: 16 AWG
    • Class K: 14 AWG thru 2 AW
    • Stranding per ASTM B8
  • Insulation:
    • Flame Retardant Polyvinylchloride (PVC) with clear Polyamide (nylon)
    • Color-Coded: per ICEA Method 1:
    • Table E-2 (does not include white or green) All with alpha-numeric designations.
  • Jacket:
    • Flame Retardant Polyvinylchloride (PVC) – yellow or black

PVC/PVC Thermoplastic Festoon Control Cable Applications:

  • Cranes and hoists
  • Festooning systems
  • Track systems
  • ROBOTS
  • Conveyors
  • Telescoping jetways

PVC/PVC Thermoplastic Festoon Control Cable Features:

  • Rated at 105°C
  • Designed for continuous extreme flexing applications
  • Anti-coiling in festoon applicationsm
  • Small bending radii
  • Flat construction allows for stacking
  • Oil and chemical resistant
  • Indoor or outdoor use
  • Meets cold bend test at -55°C
Part NumberAWG SizeNo. of Cond.Conductor StrandingApprox LBS/MFTNom. Insul. Thick. (in)Jacket ThickApprox Dimension
122655-1816465/3491.030.035.200 x .580
122660-1816865/34173.030.035.200 x 1.110
122665-18161265/34253.030.035.200 x 1.605
122670-1814441/30116.030.035.210 x .710
122675-1814841/30224.030.035.210 x 1.175
122680-18141241/30330.030.035.210 x 1.700
122685-1812465/30160.030.035.230 x .710
122690-1812565/30195.030.035.230 x .865
182840-1812765/30271.030.035.230 x 1.340
122695-1812865/30307.030.035.230 x 1.650
122700-18104105/30241.030.045.270 x .880
122705-1884168/30405.045.045.365 x 1.190
122710-1864266/30612.060.045.430 x 1.450
166005-1865266/30747.060.045.430 x 1.735
122720-1844420/30750.060.045.490 x 1.690
122725-1824665/301273.060.045.560 x 1.955