Project Description

UL 1275 / UL 1056 Hook Up Wire
UL 1275 / UL 1056 Hook Up Wire
Polyvinylchloride (PVC)
Heavy Wall Lead Wire, Hook Up Wire and Refrigeration
(105°C) (VW-1 & Moisture Resistant) (600 Volts) (UL & CSA)
RoHS Hook-up Wire RoHS Compliant
UL 1275 / UL 1056 Applications:
- UL 1275 Lead Wire: UL 1275 may be used for internal wiring of refrigerating equipment. UL 1275 is resistant to oil at temperatures not exceeding 60°C or 80°C if applicable.
- UL 1056 Lead Wire: UL 1056 may be used for internal wiring of indoor or outdoor refrigerating equipment – UL 1056 is oil resistance 60°C or 80°C (if applicable).
Customization Services for UL 1275/UL 1056 Hook Up Wire include:
Part Number | AWG Size | Conductor Stranding | Nom. O.D. (in) | Nom. Insul. Thick. (in) | Approx LBS/MFT |
1056-18-16B | 18 | 16/30 | 0.1700 | 0.063 | 18 |
1056-18-16T | 18 | 16/30 | 0.1740 | 0.060 | 18 |
1056-16-26B | 16 | 26/30 | 0.1820 | 0.063 | 22 |
1056-16-26T | 16 | 26/30 | 0.1860 | 0.060 | 22 |
1056-14-41T | 14 | 41/30 | 0.1960 | 0.060 | 28 |
1056-12-65B | 12 | 65/30 | 0.2120 | 0.060 | 37 |
1056-10-105B | 10 | 105/30 | 0.2400 | 0.060 | 53 |
UL 1276 / UL 1060 Hook Up Wire
UL 1276 / UL 1060 Hook Up Wire
Polyvinylchloride (PVC)
Heavy Wall Lead Wire, Hook Up Wire and Refrigeration
(105°C) (VW-1 & Moisture Resistant) (600 Volts) (UL & CSA)
RoHS Hook-up Wire RoHS Compliant
UL 1276 / UL 1060 Hook Up Wire Applications:
- UL 1276 Lead Wire: UL 1276 may be used for internal wiring of indoor or outdoor refrigerating equipment – UL 1276 is oil resistance 60°C or 80°C – moisture resistance 60°C.
- UL 1060 Lead Wire: UL 1060 may be used for internal wiring of electric refrigerating equipment or room air conditioners or room cooler units or remote outdoor condensing units for domestic cooling systems. UL 1060 is resistant to oil at a temperature not exceeding 60°C or 80°C, whichever is applicable.
Customization Services for UL 1276/UL 1060 Hook Up Wire include:
Part Number | AWG Size | Conductor Stranding | Nom. Insul. Thick. (in) | Nom. O.D. (in) | Approx LBS/MFT |
1060-16B | 16 | 26/30 | 0.078 | 0.2200 | 29 |
1060-14B | 14 | 41/30 | 0.078 | 0.2280 | 36 |
1060-14T | 14 | 41/30 | 0.080 | 0.2340 | 36 |
1060-12B | 12 | 65/30 | 0.078 | 0.2480 | 46 |
1060-10B | 10 | 105/30 | 0.078 | 0.2810 | 63 |
1060-10T | 10 | 105/30 | 0.080 | 0.2800 | 63 |
UL 1275 and UL 1056 are mentioned together; likewise with UL 1276 and UL 1060. Each pair of types has differences in stranding and overall construction that allow for better use in different refrigeration applications.