Project Description

TGGT Wire – UL 5256 / UL 5214 (600 Volts)
TGGT Wire
High Temperature Wire
250°C, 600 Volts
UL 5256, UL 5214 and CSA AWM Class 1, Group A/B
High Temperature Wire
250°C, 600 Volts
UL 5256, UL 5214 and CSA AWM Class 1, Group A/B
TGGT Wire Description:
- Conductor: TGGT Wire features flexible, stranded nickel-coated copper conductor.
- Insulation: PTFE tapes covered by wrapped fiberglass yarns. UL 5256 TGGT Wire has fiberglass (hi-temp) braid jacket applied over the insulation. It is then
- treated with a high-temp saturant.
- Colors: Tan (Natural) is stocked. Other colors may be available upon request.
TGGT Wire Applications:
- UL 5214 TGGT Wire may be used for internal wiring of commercial, industrial and household ovens, cooking and drying equipment. UL 5256 TGGT Wire is suited for severe hot spot locations in industrial processing.
Customization Services for TGGT Wire include:
Part Number | AWG Size | Conductor Stranding | Nom. Insul. Thick. (in) | Nom. O.D. (in) | UL Style | Approx LBS/MFT |
TG 24 | 24 | 7/.0080 | 0.007 | 0.0550 | 5256 | 4.75 |
TG 22 | 22 | 7/.0100 | 0.007 | 0.0650 | 5256 | 6.5 |
TG 20 | 20 | 10/.0100 | 0.007 | 0.0700 | 5256 | 10 |
TG 18 | 18 | 16/.0100 | 0.007 | 0.0780 | 5256 | 13 |
TG 16 | 16 | 26/.0100 | 0.011 | 0.0920 | 5256 | 17 |
TG 14 | 14 | 41/.0100 | 0.011 | 0.1130 | 5256 | 23 |
TG 12 | 12 | 65/.0100 | 0.011 | 0.1270 | 5256 | 32 |
TG 10 | 10 | 105/.0100 | 0.011 | 0.1550 | 5256 | 48 |
TG 8 | 8 | 133/.0111 | 0.011 | 0.2100 | 5256 | 72 |
TG 6 | 6 | 133/.0142 | 0.015 | 0.3100 | 5214 | 120 |
TG 4 | 4 | 133/.0177 | 0.015 | 0.3270 | 5256 | 175 |
TG 2 | 2 | 133/.0223 | 0.015 | 0.4350 | 5214 | 270 |
TGGT Cable – UL 5196 / UL 5251 (600 Volts)
TGGT Cable
High Temperature Wire
600 Volts
Single Conductor Wire
250°C, UL 5196 / UL 5251 CSA AWC Class 1 Group A/B
High Temperature Wire
600 Volts
Single Conductor Wire
250°C, UL 5196 / UL 5251 CSA AWC Class 1 Group A/B
TGGT Cable Construction:
- Conductor: TGGT Cable features single, stranded, nickel-coated copper conductor.
- Insulation: PTFE tapes covered by fiberglass covers TGGT Cable.
- Jacket: TGGT Cable has fiberglass(hi-temp) braid jacket overall.
TGGT Cable Ratings and Approvals:
- Temperature Rating: 250°C
- Voltage Rating: 600 volts
- UL & CSA: UL 5196 / UL 5251 CSA AWC Class 1 Group A/B
TGGT Cable Applications:
- TGGT Cable may be used for internal wiring of commercial, industrial and household ovens, cooking and drying equipment. TGGT Cable is suited for severe hot spot locations in industrial processing.
Customization Services for TGGT Wire include:
Part Number | AWG Size | Conductor Stranding | Nom. Insul. Thick. (in) | Nom. O.D. (in) | Approx LBS/MFT | UL Style |
TGGT-24 | 24 | 7/.0080 | 0.015 | 0.0850 | 4.75 | 5256 |
TGGT-22 | 22 | 7/.0100 | 0.015 | 0.0900 | 8 | 5196 |
TGGT-20 | 20 | 10/.0100 | 0.015 | 0.1000 | 10 | 5196 |
TGGT-18 | 18 | 16/.0100 | 0.015 | 0.1100 | 13 | 5196 |
TGGT-16 | 16 | 26/.0100 | 0.015 | 0.1200 | 17 | 5196 |
TGGT-14 | 14 | 41/0100 | 0.015 | 0.1350 | 23 | 5196 |
TGGT-12 | 12 | 65/.0100 | 0.015 | 0.1550 | 32 | 5196 |
TGGT-10 | 10 | 105/.0100 | 0.015 | 0.1800 | 48 | 5196 |
TGGT-08 | 8 | 133/.0111 | 0.015 | 0.2300 | 72 | 5196 |
TGGT-06 | 6 | 133/.0142 | 0.020 | 0.3200 | 120 | 5196 |
TGGT-04 | 4 | 133/.0177 | 0.020 | 0.3750 | 175 | 5196 |
TGGT-02 | 2 | 133/.0223 | 0.020 | 0.4450 | 270 | 5251 |
TGGT-01 | 1 | 259/.0177 | 0.020 | 0.4850 | 340 | 5251 |
TGGT-1/0 | 1/0 | 259/.0202 | 0.020 | 0.5350 | 415 | 5251 |
TGGT-2/0 | 2/0 | 259/.0229 | 0.020 | 0.5850 | 510 | 5251 |
TGGT-3/0 | 3/0 | 259/.0255 | 0.020 | 0.6450 | 630 | 5251 |
TGGT-4/0 | 4/0 | 259/.0286 | 0.020 | 0.7100 | 780 | 5251 |
TGGT Wire – UL 5180 (300 Volts)
TGGT Cable
High Temperature Wire
250°C, 300 Volts
UL 5180 & CSA AWM Class 1, A/B
High Temperature Wire
250°C, 300 Volts
UL 5180 & CSA AWM Class 1, A/B
TGGT Wire Description:
- Conductor: 300 Volt TGGT Cable features flexible, stranded nickel-coated copper conductor.
- Insulation: PTFE tapes covered by wrapped fiberglass yarns. UL 5180 TGGT Cable has fiberglass (hi-temp) braid jacket applied over the insulation. It is then treated with a high-temp saturant.
- Colors: Tan (Natural) is stocked. Other colors available upon request.
TGGT Cable Applications:
- UL 5180 TGGT Cable may be used for internal wiring of commercial, industrial and household ovens, cooking and drying equipment. UL 5180 TGGT Cable is suited for severe hot spot locations in industrial processing.
Customization Services for TGGT Wire include:
Part Number | AWG Size | Conductor Stranding | Nom. Insul. Thick. (in) | Nom. O.D. (in) | Approx LBS/MFT | UL Style |
5180-24 | 24 | 7/.0080 | 0.004 | 0.0650 | 4 | 5180 |
5180-22 | 22 | 7/.0100 | 0.004 | 0.0740 | 5 | 5180 |
5180-20 | 20 | 10/.0100 | 0.004 | 0.0810 | 6 | 5180 |
5180-18 | 18 | 16/.0100 | 0.004 | 0.0900 | 9 | 5180 |
5180-16 | 16 | 26/.0100 | 0.008 | 0.1040 | 13 | 5180 |
5180-14 | 14 | 41/.0100 | 0.008 | 0.1190 | 20 | 5180 |
5180-12 | 12 | 65/.0100 | 0.008 | 0.1330 | 29 | 5180 |
5180-10 | 10 | 105/.0100 | 0.008 | 0.1630 | 42 | 5180 |
5180-8 | 8 | 133/.0111 | 0.008 | 0.2260 | 67 | 5180 |