XLP/PVC Tray Cable (600 Volts)

HomeTray Cable and Instrumentation CableXLP/PVC Tray Cable (600 Volts)
XLP/PVC Tray Cable (600 Volts) 2017-06-29T10:32:40+00:00

Project Description

Unshielded Multi-Conductor XLP/PVC Tray Cable

XHHW Tray Cable (XLP/PVC)
-40°C to 90°C Control Cable
Type XHHW-2 Conductors

XHHW Tray Cable (XLP/PVC) Construction:

  • Conductor: 18 AWG – 10 AWG Class B Stranded Bare Copper (per ASTM B-3 and B-8)
  • Insulation: Flame-Retardant Cross-Linked Polyethylene (XLP)
  • Jacket: Black sunlight and moisture resistant Polyvinyl Chloride (PVC)

XHHW Tray Cable (XLP/PVC) Features:

  • Rated 90°C wet or dry
  • Sunlight and weather resistant
  • Excellent abrasion and chemical resistance
  • Oil resistant I jacket

XHHW Tray Cable (XLP/PVC) Applications:

  • Constructions of 3 or more conductors are permitted by NEC for TC-ER (exposed run)
  • Approved for Class I Division 2 hazardous locations per NEC Article 501 (TC)
  • Designed for use in conduit, cable tray or direct burial
  • Applications include control, power lighting and telemetering where a heat and electrically stable insulation is required
  • NEC Article 336 applications

XHHW Tray Cable (XLP/PVC) Approvals:

  • UL 1277 Type TC-ER, UL 1685, UL 44 XHHW-2 rated
  • ICEA S-95-658 (NEMA WC70)
  • Passes IEEE 383 Flame Test (70,000 btu)
  • EPA 40 CFR, Part 261, Subpart C, heavy metals per Table 1, TCLP method
Part NumberAWG SizeNo. of Cond.Conductor StrandingNom. Insul. Thick. (in)Jacket ThickNom. O.D. of Cable (in)Approx LBS/MFT
XLP/PVC 18-2C-FL1827/.01520.030.0450.202 x 0.30840
XLP/PVC 18-2C1827/.01520.030.0450.3144
XLP/PVC 18-3C1837/.01520.030.0450.32755
XLP/PVC 18-4C1847/.01520.030.0450.35567
XLP/PVC 18-5C1857/.01520.030.0450.38680
XLP/PVC 18-7C1877/.01520.030.0450.418103
XLP/PVC 18-9C1897/.01520.030.0450.485129
XLP/PVC 18-12C18127/.01520.030.0450.542180
XLP/PVC 18-15C18157/.01520.030.060.632217
XLP/PVC 18-19C18197/.01520.030.060.664261
XLP/PVC 16-2C-FL1627/.01920.030.0450.214 x 0.33453
XLP/PVC 16-2C1627/.01920.030.0450.33453
XLP/PVC 16-3C1637/.01920.030.0450.35368
XLP/PVC 16-4C1647/.01920.030.0450.38485
XLP/PVC 16-5C1657/.01920.030.0450.418101
XLP/PVC 16-7C1677/.01920.030.0450.454133
XLP/PVC 16-9C1697/.01920.030.060.558183
XLP/PVC 16-12C16127/.01920.030.060.622231
XLP/PVC 16-15C16157/.01920.030.060.688280
XLP/PVC 16-19C16197/.01920.030.060.724339
XLP/PVC 16-25C16257/.01920.030.080.884469
XLP/PVC 16-30C16307/.01920.030.080.933545
XLP/PVC 16-37C16377/.01920.030.081.004819
XLP/PVC 14-2C-FL1427/.02420.030.0450.228 x 0.36282
XLP/PVC 14-2C1427/.02420.030.0450.36273
XLP/PVC 14-3C1437/.02420.030.0450.38395
XLP/PVC 14-4C1447/.02420.030.0450.418118
XLP/PVC 14-5C1457/.02420.030.0450.456141
XLP/PVC 14-7C1477/.02420.030.0450.496187
XLP/PVC 14-9C1497/.02420.030.060.609256
XLP/PVC 14-12C14127/.02420.030.060.68325
XLP/PVC 14-15C14157/.02420.030.060.754395
XLP/PVC 14-19C14197/.02420.030.060.794479
XLP/PVC 14-25C14257/.02420.030.080.968660
XLP/PVC 14-30C14307/.02420.030.080.983769
XLP/PVC 14-37C14377/.02420.030.081.1021342
XLP/PVC 12-2C-FL1227/.03050.030.0450.248 x 0.40290
XLP/PVC 12-2C1227/.03050.030.0450.40290
XLP/PVC 12-3C1237/.03050.030.0450.427121
XLP/PVC 12-5C1257/.03050.030.0450.51173
XLP/PVC 12-7C1277/.03050.030.0450.556200
XLP/PVC 12-9C1297/.03050.030.060.681267
XLP/PVC 12-12C12127/.03050.030.060.763336
XLP/PVC 12-15C12157/.03050.030.060.848433
XLP/PVC 12-19C12197/.03050.030.080.938564
XLP/PVC 12-25C12257/.03050.030.081.092691
XLP/PVC 12-30C12307/.03050.030.081.1551046
XLP/PVC 12-37C12377/.03050.030.081.2461610
XLP/PVC 10-2C-FL1027/.03850.030.0450.271 x 0.448120
XLP/PVC 10-2C1027/.03850.030.0450.448120
XLP/PVC 10-3C1037/.03850.030.0450.476165
XLP/PVC 10-5C1057/.03850.030.060.602273
XLP/PVC 10-7C1077/.03850.030.060.655369
XLP/PVC 10-9C1097/.03850.030.060.765467
XLP/PVC 10-12C10127/.03850.030.080.899639
Shielded Multi-Conductor XLP/PVC Tray Cable

XHHW Tray Cable (XLP/PVC)
-40°C to 90°C Control Cable
Type XHHW-2 Conductors

XHHW Tray Cable (XLP/PVC) Construction:

  • Conductor: 18 AWG – 16 AWG Class B Stranded Bare Copper (per ASTM B-3 and B-8)
  • Insulation: Flame-Retardant Cross-Linked Polyethylene (XLP)
  • Jacket: Black sunlight and moisture resistant Polyvinyl Chloride (PVC)
  • Shield: 100% coverage, aluminum/polyester foil shield

XHHW Tray Cable (XLP/PVC) Features:

  • Rated 90°C wet or dry
  • Sunlight and weather resistant
  • Excellent abrasion and chemical resistance
  • Oil resistant I jacket

XHHW Tray Cable (XLP/PVC) Applications:

  • Constructions of 3 or more conductors are permitted by NEC for TC-ER (exposed run)
  • Approved for Class I Division 2 hazardous locations
  • Designed for use in conduit, cable tray or direct burial
  • Ideal for use in control, power lighting and telemetering applications where a heat and electrically stable insulation is required

XHHW Tray Cable (XLP/PVC) Approvals:

  • UL 1277 Type TC-ER, UL 1685 and UL 44 XHHW-2 rated
  • ICEA S-95-658 (NEMA WC70)
  • Passes IEEE 383 Flame Test (70,000 btu)
  • EPA 40 CFR, Part 261, Subpart C, heavy metals per Table 1, TCLP method
Part NumberAWG SizeNo. of Cond.Conductor StrandingNom. Insul. Thick. (in)Jacket ThickNom. O.D. of Cable (in)
XLP/PVC 18-2C-S1827/.01520.030.0450.314
XLP/PVC 18-3C-S1837/.01520.030.0450.331
XLP/PVC 18-4C-S1847/.01520.030.0450.359
XLP/PVC 18-5C-S1857/.01520.030.0450.39
XLP/PVC 18-7C-S1877/.01520.030.0450.422
XLP/PVC 18-9C-S1897/.01520.030.0450.489
XLP/PVC 18-12C-S18127/.01520.030.0450.546
XLP/PVC 16-2C-S1627/.01920.030.0450.338
XLP/PVC 16-3C-S1637/.01920.030.0450.357
XLP/PVC 16-4C-S1647/.01920.030.0450.388
XLP/PVC 16-5C-S1657/.01920.030.0450.422
XLP/PVC 16-7C-S1677/.01920.030.0450.458
XLP/PVC 16-9C-S1697/.01920.030.060.562
XLP/PVC 16-12C-S16127/.01920.030.060.626
XLP/PVC 14-2C-S1427/.02420.030.0450.366
XLP/PVC 14-3C-S1437/.02420.030.0450.387
XLP/PVC 14-4C-S1447/.02420.030.0450.422
XLP/PVC 14-5C-S1457/.02420.030.0450.46
XLP/PVC 14-7C-S1477/.02420.030.0450.5
XLP/PVC 14-12C-S14127/.02420.030.060.684
XLP/PVC 12-2C-S1227/.03050.030.0450.406
XLP/PVC 12-3C-S1237/.03050.030.0450.431
XLP/PVC 12-4C-S1247/.03050.030.0450.471
XLP/PVC 12-5C-S1257/.03050.030.0450.514
XLP/PVC 12-7C-S1277/.03050.030.060.59
XLP/PVC 12-12C-S12127/.03050.030.060.767
XLP/PVC 10-2C-S1027/.03850.030.0450.452
XLP/PVC 10-3C-S1037/.03850.030.0450.48
XLP/PVC 10-4C-S1047/.03850.030.060.556
XLP/PVC 10-5C-S1057/.03850.030.060.606
XLP/PVC 10-7C-S1077/.03850.030.060.659
Multi-Conductor XLP/PVC Tray Cable with Ground

Grounded XHHW Tray Cable (XLP/PVC)
-40°C to 90°C Power Cable
Type XHHW-2 Conductors

Grounded XHHW Tray Cable (XLP/PVC) Construction:

  • Conductor: 8 AWG – 1 AWG Class B Stranded Bare Copper (per ASTM B-33 and B-8)
  • Insulation: Flame-Retardant Cross-Linked Polyethylene (XLP)
  • Jacket: Black sunlight and moisture resistant Polyvinyl Chloride (PVC)

Grounded XHHW Tray Cable (XLP/PVC) Features:

  • Rated 90°C wet or dry
  • Sunlight and weather resistant
  • Excellent abrasion and chemical resistance
  • Oil resistant I jacket

Grounded XHHW Tray Cable (XLP/PVC) Applications:

  • Constructions of 3 or more conductors are permitted by NEC for TC-ER (exposed run)
  • Approved for Class 1 Division 2 hazardous locations per NEC Article 501 (TC)
  • Designed for use in conduit, cable tray or direct burial
  • Suitable for use in control, power lighting and telemetering applications where a heat and electrically stable insulation is required
  • NEC Article 336 applications

Grounded XHHW Tray Cable (XLP/PVC) Approvals:

  • UL 1277 Type TC-ER, UL 1685, and UL 44 XHHW-2 rated
  • ICEA S-95-658 (NEMA WC70)
  • Passes IEEE 383 flame test (70,000 btu)
  • EPA 40 CFR, Part 261, Subpart C, heavy metals per Table 1, TCLP method
Part NumberAWG SizeNo. of Cond.Conductor StrandingGround AWG SizeNom. Insul. Thick. (in)Jacket ThickNom. O.D. of Cable (in)Approx LBS/MFT
XLP/PVC 8-3C-G837/.0486100.030.060.603292
XLP/PVC 8-4C-G847/.0486100.030.060.664364
XLP/PVC 6-3C-G637/.061280.030.060.681424
XLP/PVC 6-4C-G647/.061280.030.060.748532
XLP/PVC 4-3C-G437/.077280.040.080.877658
XLP/PVC 4-4C-G447/.077280.040.080.962831
XLP/PVC 2-3C-G237/.097460.040.081967
XLP/PVC 2-4C-G247/.097460.040.081.1071228
XLP/PVC 1-3C-G1319/.066460.060.0851.1441216
XLP/PVC 1-4C-G1419/.066460.060.0851.2611554
XLP/PVC 1/0-3C-G1/0319/.074560.060.0851.231430
XLP/PVC 1/0-4C-G1/0419/.074560.060.0851.3311832
XLP/PVC 2/0-3C-G2/0319/.083760.060.0851.3361729
XLP/PVC 2/0-4C-G2/0419/.083760.060.0851.4762230
XLP/PVC 3/0-3C-G3/0319/.094040.060.0851.4422144
XLP/PVC 4/0-3C-G4/0319/.105540.060.0851.743403
XLP/PVC 4/0-4C-G4/0419/.105540.060.0851.8083976
XLP/PVC 250-3C-G250337/.082240.070.121.8573014
XLP/PVC 250-4C-G250437/.082240.070.121.6154038
XLP/PVC 350-3C-G350337/.097430.070.122.2224254
XLP/PVC 350-4C-G350437/.097430.070.122.0095519
XLP/PVC 500-3C-G500337/.116220.070.122.2945846
XLP/PVC 500-4C-G500437/.116220.070.122.5417612
Multi-Paired XLP/PVC Tray Cable (POS)

POS Tray Cable (XLP/PVC)
-40°C to 90°C Instrumentation Cable

POS Tray Cable (XLP/PVC) Construction:

  • Conductor: 18 AWG – 16 AWG Class B Stranded Bare Copper (per ASTM B-33 and B-8)
  • Insulation: Flame-Retardant Cross-Linked Polyethylene (XLP)
  • Color Code: Black/White; Alpha/numeric print
  • Jacket: Black sunlight and moisture resistant Polyvinyl Chloride (PVC)
  • Shield: Overall 100% coverage, aluminum/polyester foil shield

POS Tray Cable (XLP/PVC) Features:

  • Rated 90°C wet or dry
  • Sunlight and weather resistant
  • Superior low temperature cold bend characteristics
  • Excellent abrasion and chemical resistance
  • Flame resistant jacket burns to ash and limited thermoplastic drip

POS Tray Cable (XLP/PVC) Applications:

  • Approved for Class 1 Division 2 hazardous locations per NEC Article 501 (TC)
  • Designed for use in conduit, cable tray or direct burial
  • Suitable for use in industrial and utility applications where reliability and performance are paramount
  • NEC Article 336 applications

POS Tray Cable (XLP/PVC) Approvals:

  • UL 1277 Type TC, UL 1581, and UL 1685 approved
  • ICEA S-73-532 and ICEA S-95-658 rated
  • Passes IEEE 383 Flame Test (70,000 btu)
  • EPA 40 CFR, Part 261, Subpart C, heavy metals per Table 1, TCLP method
Part NumberAWG SizeNo. of PairsConductor StrandingNom. Insul. Thick. (in)Jacket ThickNom. O.D. of Cable (in)Approx LBS/MFT
XLP/PVC 18-1P-S1817/.01520.030.0450.31445
XLP/PVC 18-2P-S1827/.01520.030.0450.47689
XLP/PVC 18-4P-S1847/.01520.030.0450.582156
XLP/PVC 18-8P-S1887/.01520.030.060.733255
XLP/PVC 18-12P-S18127/.01520.030.060.902383
XLP/PVC 18-24P-S18247/.01520.030.081.198665
XLP/PVC 18-36P-S18367/.01520.030.081.36909
XLP/PVC 16-1P-S1617/.01920.030.0450.33856
XLP/PVC 16-2P-S1627/.01920.030.0450.548184
XLP/PVC 16-4P-S1647/.01920.030.060.632218
XLP/PVC 16-8P-S1687/.01920.030.060.8328
XLP/PVC 16-12P-S16127/.01920.030.080.988496
XLP/PVC 16-16P-S16167/.01920.030.081.108625
XLP/PVC 16-24P-S16247/.01920.030.081.312869
XLP/PVC 16-36P-S16367/.01920.030.081.531258
Multi-Paired XLP/PVC Tray Cable (SPOS)

SPOS Tray Cable (XLP/PVC)
-40°C to 90°C Instrumentation Cable

SPOS Tray Cable (XLP/PVC) Construction:

  • Conductors: 18 AWG – 16 AWG Class B stranded bare copper per ASTM B-33 and B-8
  • Insulation: Flame-retardant Cross-linked polyethylene (XLP)
  • Color-Code: Black/White; Alpha/numeric print
  • Shield: Individual and overall 100% coverage, aluminum/polyester foil shield
  • Jacket: Black sunlight and moisture resistant Polyvinyl Chloride (PVC)

XLP/PVC SPOS Tray Cable Features:

  • Rated 90°C wet or dry
  • Sunlight and weather resistant
  • Superior low temperature cold bend characteristics
  • Excellent abrasion and chemical resistance
  • Flame resistant jacket burns to ash and limited thermoplastic drip

SPOS Tray Cable (XLP/PVC) Applications:

  • Approved for Class 1 Division 2 hazardous location per NEC Article 501 (TC)
  • Designed for use in conduit, cable tray, or direct burial
  • Developed for use in industrial and utility applications

SPOS Tray Cable (XLP/PVC) Approvals:

  • UL 1277 Type TC, UL 1581, and UL 1685 approved
  • ICEA S-73-532 and ICEA S-95-658 (WC70) rated
  • Passes IEEE 383 Flame Test (70,000 btu)
  • EPA 40 CFR, Part 261, Subpart C, heavy metals per Table 1, TCLP method
Part NumberAWG SizeNo. of PairsConductor StrandingNom. Insul. Thick. (in)Nom. O.D. of Cable (in)Approx LBS/MFT
XLP/PVC 18-2P-SPOS1827/.01520.030.4998
XLP/PVC 18-4P-SPOS1847/.01520.030.598176
XLP/PVC 18-8P-SPOS1887/.01520.030.755290
XLP/PVC 18-12P-SPOS18127/.01520.030.93438
XLP/PVC 18-24P-SPOS18247/.01520.031.254796
XLP/PVC 18-36P-SPOS18367/.01520.031.442968
XLP/PVC 16-2P-SPOS1627/.01920.030.562140
XLP/PVC 16-4P-SPOS1647/.01920.030.674227
XLP/PVC 16-8P-SPOS1687/.01920.030.8375
XLP/PVC 16-12P-SPOS16127/.01920.031.015571
XLP/PVC 16-24P-SPOS16247/.01920.031.3681044
XLP/PVC 16-36P-SPOS16367/.01920.031.5741477